Technical Specifications of the Metering Station 60/60-2500
This is the 3rd type of civic stations having the same dimensions as model 60/601000 that depending on the location of installation can be manufactured in flat and cabinet types. Drawing of this station is generally designed as bilinear (double line) each line having the ability to transfer 2500m3 of gas. The station's specifications are as follows:
• Inlet pressure: 45-60psig (3.06-4.08bar)
• Outlet pressure: 45-60psig (3.06-4.08bar)
• Size of inlet pipe: NPS = 4"
• Size of outlet pipe: NPS = 4"
• Capacity: 2500m3/h
• Meter type: turbine G400
• Connection: flanged
• Radiography: 100%
• Designing pressure: 90psi
• Testing pressure: 120psi
• Designing temperature: -10 to +60 °C
• Class: ANSI 150
• Standards of designing, manufacturing, and testing: ASME CODE SEC VIII, API 1104, ASME B 31.3, ASME CODE SEC IX,…
• Shape of station: double line
• Capacity of each line: 2500m3/h